<?xml version="1.0" encoding="UTF-8" ?>



<rss version="2.0" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#">

<channel>
<title><![CDATA[医疗设备维修]]> </title>
<description>
<![CDATA[医疗电路板及其电源显示器维修.承接飞利浦GE彩超维修各类除颤监护仪维修！代理希森美康贝克曼检验设备维修！]]>
</description>
<link>http://dianziweixiu.blog.bokee.net/</link>
<language>zh-cn</language>
<creator>dianziweixiu</creator>
<pubDate>Fri, 30 Mar 2007 17:02:04 CST </pubDate>
<generatorAgent rdf:resource="http://www.bokee.net"/>
<ttl>5</ttl>

<item>
<title>FUJIFILM  DRY PIX3000相机维修富士3000相机维修 电源维修</title>
<link>http://www.bokee.net/blogmodule/weblogcomment_viewEntry/10099106.html</link>
<description>
<![CDATA[<p><img alt="" src="http://fs01.bokee.net/userfilespace/2012/02/06/dianziweixiu17372795.bmp" /><img height="375" width="500" alt="" src="http://fs01.bokee.net/userfilespace/2012/02/06/dianziweixiu17372815.jpg" />FUJIFILM&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr> DRY PIX3000维修各类拍片机电源维修 各类激光相机电源维修 各种干式相机电源维修</p>
<p>各种相机电路板维修 各类医疗设备电路板维修 各种医用电源维修 维修电话13391816794</p>
<p><img height="375" width="500" alt="" src="http://fs01.bokee.net/userfilespace/2012/02/06/dianziweixiu17372929.jpg" /></p>
<p>1。报0004错误</p>
<p>机器左边的一个行程开关的断线</p>
<p>2。机器打出的胶片是全黑的</p>
<p>重新校正，检查热敏头和控制板</p>
<p>日常一定要注意热敏头的清洁，一定要关机后再清洁处理，另外光密度计及风扇的灰尘的清洁也很重要</p>
<p>3。问题：机器连续打印几张后打印速度（反应）太慢</p>
<p>分析：热敏头散热风扇电源线没有连接好，造成热敏头不能冷却，当连续打印几张后热敏头温度迅速升高并超出热敏头的工作温度，系统即停止工作并等待温度降低，从而造成&ldquo;机器连续打印几张后打印速度（反应）太慢&rdquo;的现象</p>
<p>解决：重新连接电源线</p>
<p>4。主机（CT MR CR DR)打印机发出数据，提示不能连接到打印机，并且时断时续<br />
&nbsp;&nbsp;&nbsp; 使用同一局域网中的工作站，ping 打印机ip，发现，平时可以ping的通，一旦CT发出打印命令，就变成连接超时。工作站，与CT之间图像传输一直处于正常状态。<br />
&nbsp;&nbsp;&nbsp; 交换机故障，排除，（换过多个交换机，故障仍存在）<br />
&nbsp;&nbsp;&nbsp; 网线故障，排除，（互换过网线，故障仍存在）</p>
<p>指导：从CT发送打印指令，传输数据到打印机，除了网络交换机以外，还有其他设备吗？如DRYOIX LINK DICOM转换器之类，或KODAK MIM100等，看看这些中间设备有没有内存不足问题。</p>
<p>专业维修：富士激光相机电源电路板　AGFA相机电源电路板　柯达相机电源电路板　柯尼卡激光相机电源电路板　西本相机电源电路板　　承接维修各类电路板，电源，显示器．维修特点：电路板芯片级无图纸维修</p>
<p align="left"><b>我公司承接医院维修　代理厂家售后维修　</b><b>维修电话：13391816794 维修在线QQ283536127</b></p>
<p align="left">我公司跟全国各地激光相机代理公司&nbsp;<wbr></wbr><wbr></wbr> 有长期维修电源电路板显示器的合作</p>
<p align="left"><strong>全国激光相机电源维修中心：</strong>富士公司跟我公司有长期合作<strong>；</strong>AGFA很多维修公司跟我公司有长期合作；柯达有很多公司也在我公司长期维修各种电源，显示器；柯尼卡很多工程师在我这里维修过电源电路板显示器；西本也有相当一部分工程师跟我公司有长期合作。还有其他品牌的激光相机都在我公司维修过电源或者显示器。需要维修激光相机电源的欢迎合作。</p>
<p align="left">富士激光相机维修 AGFA相机维修 柯达相机维修 柯尼卡相机维修 西本相机维修泛太平洋相机维修</p>
<!--
<div id="miniAd" style="display:none;padding-top:20px"></div>
-->]]>
</description>
<guid isPermaLink="false">http://www.bokee.net/blogmodule/weblogcomment_viewEntry/10099106.html</guid>
<subject></subject>
<author>dianziweixiu</author>
<category></category>
<pubDate>Mon, 06 Feb 2012 13:17:49 CST </pubDate>
</item>

<item>
<title>GE四维彩超销售（GEVoluson E8/GE VIVIDE9/V730/GE LOGIQ7）飞利浦四维彩超销售（IE33/IU22/HD15/HD11/HD9）</title>
<link>http://www.bokee.net/blogmodule/weblogcomment_viewEntry/10075989.html</link>
<description>
<![CDATA[<p>飞利浦四维彩超销售（IE33/IU22/HD15/HD11/HD9）现货机器，欢迎订购，欢迎看机器！另外现场维修飞利浦所有机型机器！飞利浦IU22&nbsp;飞利浦IE33&nbsp;飞利浦HD11&nbsp;飞利浦HD15&nbsp;飞利浦HD9&nbsp;飞利浦HD7/HD6/HD3&nbsp;销售配件维修 飞利浦HDI5000/4000/3500销售配件维修&nbsp; <strong><font color="#ed1c24">电话13391816794&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr>QQ283536127</font></strong></p>
<p><span style="font-size: 12px"><strong>GE四维彩超销售 GE彩超销售&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr>GE彩超维修&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr>GE彩超配件&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr>GE彩超电源维修&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr>GE彩超显示器维修&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr>GE彩超电路板维修&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr>GE彩超显示屏维修&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr>GE彩超探头维修&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr>GE彩超销售GE彩超维修（GEVoluson&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr>E8/e6&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr>/GEV730/GE&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr>VIVIDE9/7/3/4/GE&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr>LOGIQE9/9/7/5/3）等&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr> GE LOGIQ 400MD/LOGIQ 500MD/LOGIQ 700MD彩超简介配件维修&nbsp;GE&nbsp;LOGIQ&nbsp;P6&nbsp;/p5/p3销售配件维修&nbsp;&nbsp; <span style="color: #ff0000">销售所有GE机型机器，可以订购机器！超大库房欢迎来看机器！<br />
</span><font color="#ed1c24">电话13391816794&nbsp;<wbr></wbr><wbr></wbr><wbr></wbr>QQ283536127</font></strong></span>
<p><img height="384" width="284" alt="" src="http://fs01.bokee.net/userfilespace/2012/02/03/dianziweixiu17287898.jpg" /><img height="300" width="300" alt="" src="http://fs01.bokee.net/userfilespace/2012/02/03/dianziweixiu17287928.jpg" /><img alt="" src="http://fs01.bokee.net/userfilespace/2012/02/03/dianziweixiu17287962.jpg" /><img height="400" width="300" alt="" src="http://fs01.bokee.net/userfilespace/2012/02/03/dianziweixiu17287983.jpg" /><img height="375" width="500" alt="" src="http://fs01.bokee.net/userfilespace/2012/02/03/dianziweixiu17288048.jpg" /><img height="375" width="500" alt="" src="http://fs01.bokee.net/userfilespace/2012/02/03/dianziweixiu17288148.jpg" /><img height="612" width="490" alt="" src="http://fs01.bokee.net/userfilespace/2012/02/03/dianziweixiu17288170.jpg" /><img height="200" width="137" alt="" src="http://fs01.bokee.net/userfilespace/2012/02/03/dianziweixiu17288178.jpg" /><img alt="" src="http://fs01.bokee.net/userfilespace/2012/02/03/dianziweixiu17288190.jpg" /><img height="331" width="250" alt="" src="http://fs01.bokee.net/userfilespace/2012/02/03/dianziweixiu17288199.jpg" /></p>
</p>]]>
</description>
<guid isPermaLink="false">http://www.bokee.net/blogmodule/weblogcomment_viewEntry/10075989.html</guid>
<subject></subject>
<author>dianziweixiu</author>
<category></category>
<pubDate>Fri, 03 Feb 2012 13:59:16 CST </pubDate>
</item>

<item>
<title>飞利浦HD-3彩超简介销售以及维修配件</title>
<link>http://www.bokee.net/blogmodule/weblogcomment_viewEntry/10066439.html</link>
<description>
<![CDATA[<p><strong><img alt="" src="http://fs01.bokee.net/userfilespace/2012/02/02/dianziweixiu17252072.jpg" />飞利浦HD-3</strong></p>
<div align="left">&nbsp;<wbr></wbr></div>
<div align="left"><b>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 最小巧、最便捷、最灵活的高清系统</b></div>
<div align="left">&nbsp;<wbr></wbr></div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 当您选择超声检查系统时，您可能最需要的就是简洁：最轻便、最易学、最少维护和修理、价格更便宜。<b>HD3</b><b>超声检查系统</b>在满足您需求的同时，还将不在您需求之</div>
<div align="left">&nbsp;<wbr></wbr></div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 列的配置，尽量降到最少。</div>
<div align="left">&nbsp;<wbr></wbr></div>
<div align="left"><b>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 高清晰系统，体积恰好符合您的需求：</b></div>
<div align="left">&nbsp;<wbr></wbr></div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 拥有宽带数字波束形成器，比常规的窄带系统获取和保存更多的组织信息，能够提高您的诊断信心。宽动态范围和数字聚焦提供了超凡的灵敏度和细节分辨力。</div>
<div align="left">&nbsp;<wbr></wbr></div>
<div align="left"><b>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 灵活机动，可根据人体工程学进行调整：</b></div>
<div align="left">&nbsp;<wbr></wbr></div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> HD3体积轻巧，可以在狭窄的空间里灵活移动。高度可调节的控制面板和独特的可折叠平板监视器可随您的需要移动。人体工程学设置降低了职业肌肉劳损的发生，并使患者能够看到检测图像。</div>
<div align="left">&nbsp;<wbr></wbr></div>
<div align="left"><b>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 性能先进、设计紧凑：</b></div>
<div align="left">&nbsp;<wbr></wbr></div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> HD3拓展了您的临床能力和患者服务：标准化产科、妇科、心脏学、血管成像及泌尿科分析和测量软件包，患者检查数据能够通过光盘或可选择的DICOM连接获得实施管理，便捷的USB接口同样可用来进行数据传输。</div>
<div align="left">
<table cellspacing="0" cellpadding="0" hspace="0" vspace="0">
    <tbody>
        <tr>
            <td valign="top" align="left">
            <div align="left">&nbsp;<wbr></wbr></div>
            <div align="left"><b>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 满足您的更多需求：</b></div>
            <ul>
                <li>
                <div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 多种扫描模式和广泛多样的应用</div>
                </li>
                <li>
                <div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 高清晰度灰阶和彩色成像</div>
                </li>
                <li>
                <div align="left">&nbsp;<wbr></wbr>清晰、无闪动的液晶屏监视器</div>
                </li>
                <li>
                <div align="left">影像回放</div>
                </li>
                <li>
                <div align="left">易操作</div>
                </li>
                <li>
                <div align="left">轻便、可移动、符合人体工程学设计</div>
                </li>
                <li>
                <div align="left">&nbsp;<wbr></wbr>组织谐波</div>
                </li>
                <li>
                <div align="left">带有综合测量、计算和报告功能的分析包</div>
                </li>
                <li>
                <div align="left">整合的CD光驱、USB闪存和可选择的DICOM工作网络。</div>
                </li>
                <li>
                <div align="left">飞利浦高质量的服务支持</div>
                </li>
            </ul>
            <p align="left"><b>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 成像模式</b></p>
            </td>
        </tr>
    </tbody>
</table>
</div>
<div align="left"><br clear="all" />
&nbsp;</div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 二维成像</div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 组织谐波成像（THI）</div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 脉冲多普勒</div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 解剖M型</div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 自由臂三维成像（Freehand 3D）</div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 可选择的彩色多普勒</div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 可选择的彩色血管能量成像（CPA）</div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 二维/彩色双重图像回放模式</div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 二维和多普勒双重模式</div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 二维、多普勒和彩色/彩色血管能量成像（CPA）三重模式</div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 高分辨率读写放大模式</div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 梯形成像</div>
<div align="left">&nbsp;<wbr></wbr></div>
<div align="left"><b>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 快速入门，轻松掌握：</b></div>
<div align="left">&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 简单的快速入门指南和自学教程光盘能够使您迅速学习和掌握使用方法，而不需要等待安装和培训。当然，如果您需要，我们保证您随时能够得到可选择的支持！</div>
<div align="left">&nbsp;</div>
<p>飞利浦彩超销售&nbsp;<wbr></wbr>飞利浦彩超维修&nbsp;<wbr></wbr>飞利浦彩超配件&nbsp;<wbr></wbr>飞利浦彩超电源维修&nbsp;<wbr></wbr>飞利浦彩超显示器维修&nbsp;<wbr></wbr>飞利浦彩超显示屏维修&nbsp;<wbr></wbr>飞利浦彩超电路板维修&nbsp;<wbr></wbr>飞利浦彩超探头维修&nbsp;<wbr></wbr>电话13391816794&nbsp;<wbr></wbr>QQ283536127</p>
<p>飞利浦HD3&nbsp;<wbr></wbr> 飞利浦HD6&nbsp;<wbr></wbr> 飞利浦HD7&nbsp;<wbr></wbr> 飞利浦HD9 飞利浦HD11 飞利浦HD15 飞利浦IU22 飞利浦IE33 维修销售配件</p>]]>
</description>
<guid isPermaLink="false">http://www.bokee.net/blogmodule/weblogcomment_viewEntry/10066439.html</guid>
<subject></subject>
<author>dianziweixiu</author>
<category></category>
<pubDate>Thu, 02 Feb 2012 14:23:53 CST </pubDate>
</item>

<item>
<title>AGFA医用配件胶片销售维修Kodak配件维修FUJIFILM配件维修</title>
<link>http://www.bokee.net/blogmodule/weblogcomment_viewEntry/10039364.html</link>
<description>
<![CDATA[<p><span><strong>医用相机维修 CR维修 DR维修 医用胶片销售 维修电话13391816794 QQ283536127</strong></span></p>
<p><span>各类医用相机的保养及维修</span></p>
<p>1. FUJIFILM：DryPix1000、2000、3000、4000、7000<br />
2. Kodak：160、DV8100、DV8200、DV8150、DV8700、DV8900</p>
<p>3.KONICA MINOLTA： 201、201A、701、 722、751、752、771、832、Li-2001<br />
2. AGFA：DryStar3000、5300、5302、5500、5503<br />
<span>各种品牌CR的保养及维修</span><br />
1. Kodak：CR500、CR800、CR850、CR900、CR950、CR975<br />
2. AGFA：ADC Solo、Compact、Compact Plus、CR25.0、CR75.0<br />
3. FUJIFILM：XG-1、XG5000、FCR5000、FCR5000R、Capsula XL<br />
4.KONICA MINOLTA： 170、190<br />
&nbsp;</p>
<p><span>单次维修：</span>为客户提供单次维修服务，根据机器故障的复杂程度、零件是否损坏、保修时间长短，收取适当的维修费用；<br />
<span>技术保修：</span>根据机器的使用情况以及客户的具体要求，在合同期为机器提供技术保修，根据更换零件的情况收取保修费用；<br />
<span>全保保修：</span>在合同期为客户机器提供全部零件的保修服务，收取合适的保修费用。</p>
<p>&nbsp;<wbr></wbr></p>
<p>专业医学影像设备维修与销售<br />
低价出售FUJIFILM(富士)7000相机&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 柯达8100 8900相机<br />
低价出售爱克发单槽多槽CR&nbsp;<wbr></wbr>&nbsp;<wbr></wbr><br />
低价出售爱克发全新IP板 需要及时跟我联系 保证最优价格<br />
<br />
&nbsp;</p>]]>
</description>
<guid isPermaLink="false">http://www.bokee.net/blogmodule/weblogcomment_viewEntry/10039364.html</guid>
<subject></subject>
<author>dianziweixiu</author>
<category></category>
<pubDate>Mon, 30 Jan 2012 13:54:11 CST </pubDate>
</item>

<item>
<title>休假 感谢 </title>
<link>http://www.bokee.net/blogmodule/weblogcomment_viewEntry/10012621.html</link>
<description>
<![CDATA[<p>&nbsp; 从明天开始本人将休假，上班时间是初八！有需要购买机器，有需要购买配件，有需要维修的朋友现在可跟你说对不起了！如果不着急初八后可以联系我！过去的一年我的感谢很多人，感谢给过我生意的人们！感谢给过我技术支持的人们，感谢给过我价格支持的人们，感谢给过我配件支持的人们，感谢帮助过我维修的工程师们，感谢给我介绍过业务的人们！感谢给过我良好意见的人们！感谢你们过去一年的支持！还希望你们在今年还接着支持我，接着给予我各个方便的帮助！感谢！</p>
<p>&nbsp;<wbr></wbr> 我本是个不学无术的孩子，生命本不值钱，感谢曾经帮助过我的人们！</p>
<p>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <wbr></wbr>&nbsp;&nbsp;<wbr></wbr>黄泽13391816794</p>
<p>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2012-1-19<wbr></wbr></p>]]>
</description>
<guid isPermaLink="false">http://www.bokee.net/blogmodule/weblogcomment_viewEntry/10012621.html</guid>
<subject></subject>
<author>dianziweixiu</author>
<category></category>
<pubDate>Thu, 19 Jan 2012 13:28:49 CST </pubDate>
</item>

<item>
<title>Sysmex UF-100/UF-50尿沉渣分析仪常见故障维修</title>
<link>http://www.bokee.net/blogmodule/weblogcomment_viewEntry/10008673.html</link>
<description>
<![CDATA[<p>
<table cellspacing="0" cellpadding="0" width="100%" border="0" style="font-weight: normal; word-break: break-all">
    <tbody>
        <tr>
            <td height="25"><span style="word-break: break-all">Sysmex仪器维修 UF-100维修 UF-50维修 东亚仪器维修 希森美康维修 QQ283536127&nbsp;<wbr></wbr> 13391816794黄</span></td>
        </tr>
        <tr>
            <td>
            <p>&nbsp;<wbr></wbr></p>
            </td>
        </tr>
        <tr>
            <td valign="top" align="left" colspan="2" height="300" style="word-break: break-all">
            <table cellspacing="0" cellpadding="10" align="left" border="0">
                <tbody>
                    <tr>
                        <td>&nbsp;</td>
                    </tr>
                </tbody>
            </table>
            <div align="left">Sysmex&nbsp;<wbr></wbr>UF-100尿沉渣分析仪常见故障维修及处理&nbsp;<wbr></wbr><br />
            故障现象：CLINITEK&nbsp;<wbr></wbr>200+与Sysmex&nbsp;<wbr></wbr>UF-100尿沉渣分析仪(UF-100尿沉渣分析仪可与尿十项CLINITEK&nbsp;<wbr></wbr>Atlas&nbsp;<wbr></wbr>、CLINITEK&nbsp;<wbr></wbr>200+、MIDitron、MIDitron&nbsp;<wbr></wbr>Jr.&nbsp;<wbr></wbr>尿机联机）与CLINITEK&nbsp;<wbr></wbr>200+尿十项联机,但联机后CLINITEK&nbsp;<wbr></wbr>200+的结果不能传到UF-100上。无法正常做标本。&nbsp;<wbr></wbr><br />
            故障原因：有两种可能：1设定值不正确（或UF-100设定错误，或CLINITEK&nbsp;<wbr></wbr>200+设定错误。）2：测试顺序不正确。&nbsp;<wbr></wbr><br />
            故障处理：仔细检查UF-100和CLINITEK&nbsp;<wbr></wbr>200+的设置。设置UF-100，打开外部数据接收功能及设置相关参数。&nbsp;<wbr></wbr><br />
            1.启动UF-100，打开外部数据接收功能及设置相关参数。Settings---Dipstick&nbsp;<wbr></wbr>Reader----Setting----在Status选择栏选择Connected；在Reader选择栏选择Clinitek&nbsp;<wbr></wbr>200+；在Cross&nbsp;<wbr></wbr>Check选择栏选择Yes；保存退出。&nbsp;<wbr></wbr><br />
            2.在Settings---Dipstick&nbsp;<wbr></wbr>Reader----&nbsp;<wbr></wbr>Get&nbsp;<wbr></wbr>Farmat&nbsp;<wbr></wbr>----在Get&nbsp;<wbr></wbr>Farmat选择栏选择&nbsp;<wbr></wbr>ENGLISH&nbsp;<wbr></wbr>CON，保存退出。&nbsp;<wbr></wbr><br />
            3.在Settings---Dipstick&nbsp;<wbr></wbr>Reader----&nbsp;<wbr></wbr>Cross&nbsp;<wbr></wbr>Check----在Cross&nbsp;<wbr></wbr>Check&nbsp;<wbr></wbr>Condition设置交叉比较范围。保存退出。&nbsp;<wbr></wbr><br />
            4.单位设置：从菜单Settings---&nbsp;<wbr></wbr>General&nbsp;<wbr></wbr>Setup-Unit-Dipstick&nbsp;<wbr></wbr>Units---在Dipstick&nbsp;<wbr></wbr>Units选择栏选择Rank和+/-，注意：&lsquo;Rank&rsquo;-&rsquo;Num&rsquo;只能选择其中一项。&lsquo;+/-&rsquo;表示是否进行比较。Num-表示接收半定性结果。&nbsp;<wbr></wbr><br />
            5.设定日期格式：Settings-General&nbsp;<wbr></wbr>Setup-Data&nbsp;<wbr></wbr>Format-在Data&nbsp;<wbr></wbr>Farmat选择栏选择yymmdd，保存退出。&nbsp;<wbr></wbr><br />
            6.设定日期/时间：Settings-General&nbsp;<wbr></wbr>Setup-Data&nbsp;<wbr></wbr>/Time-在Data/Time选择栏选择10：27，保存退出。&nbsp;<wbr></wbr><br />
            7.尿仪CLINITEK&nbsp;<wbr></wbr>200+的SEQ.ID的编号必须与UF-100的no.----&nbsp;<wbr></wbr>编号一致。如，CLINITEK&nbsp;<wbr></wbr>200+的SEQ.ID的编号为3-27，UF-100的编号为no.3-27。&nbsp;<wbr></wbr><br />
            8.设置泰利特-200+，打开外部数据接收功能及设置相关参数。启动CLINITEK&nbsp;<wbr></wbr>200+，设CLINITEK&nbsp;<wbr></wbr>Printer：OFF；Computer&nbsp;<wbr></wbr>ON；设定HANDshake&nbsp;<wbr></wbr>OFF；BAUD&nbsp;<wbr></wbr>Rate：9600；设定CHARacter&nbsp;<wbr></wbr>Bits：8；设定Parity：NONE；设定Specimen&nbsp;<wbr></wbr>ID&nbsp;<wbr></wbr>Entry：OFF；设定Identify：Abnormals；设定Display&nbsp;<wbr></wbr>of&nbsp;<wbr></wbr>SEQ：OFF；设定PLUS&nbsp;<wbr></wbr>System：ON；&nbsp;<wbr></wbr><br />
            9.设定CLINITEK&nbsp;<wbr></wbr>200+日期/时间应与UF-100一致。&nbsp;<wbr></wbr><br />
            10.设定CLINITEK&nbsp;<wbr></wbr>200+日期格式应与UF-100一致，选择yymmdd，保存退出。&nbsp;<wbr></wbr><br />
            11.注意事项：1，设定参数时要求分别单独启动，设定完毕要求保存退出后关机。2，将标准RS-232电缆线与UF-100的接口和CLINITEK&nbsp;<wbr></wbr>200+的RS-232口连接。3，先启动UF-100，再启动&nbsp;<wbr></wbr>CLINITEK&nbsp;<wbr></wbr>200+尿机，UF-100的DR出现绿色表示连接正常。4，先在尿仪上做标本，结果会自动传到UF-100上，在Dipstick&nbsp;<wbr></wbr>data菜单下可查阅结果。5，当UF-100接受到尿机的结果后，做标本得出的结果会自动与尿机相同ID号的结果进行比较并显示在同一报告上。后通过GP打印机将泰利特200+尿机测试的结果和UF-100与尿机相同ID号的结果进行比较后的结果在同一张报告单上打印出来。&nbsp;<wbr></wbr><br />
            <br />
            故障现象2：UF-100尿沉渣分析仪与尿十项CLINITEK&nbsp;<wbr></wbr>200+尿机联机正常后，Sysmex&nbsp;<wbr></wbr>UF-100尿沉渣分析仪又与计算机联机，如果尿十项的结果能在UF-100的测试报告分析画面显示出来，UF-100与CLINITEK&nbsp;<wbr></wbr>200+比较后的结果也能传到计算机上，但尿机的结果（CLINITEK&nbsp;<wbr></wbr>200+的结果）不能传到计算机上。&nbsp;<wbr></wbr><br />
            故障原因：UF-100与CLINITEK&nbsp;<wbr></wbr>200+比较后的结果能传到计算机上，但尿机的结果（CLINITEK&nbsp;<wbr></wbr>200+的结果）不能传到计算机上属正常。如果尿十项的结果能在UF-100的测试报告分析画面显示出来，UF-100与CLINITEK&nbsp;<wbr></wbr>200+比较后的结果也能传到计算机上，但CLINITEK&nbsp;<wbr></wbr>200+的结果不能传到计算机上属正常，因为Sysmex&nbsp;<wbr></wbr>UF-100尿沉渣分析仪在Settings-Configuration-HC&nbsp;<wbr></wbr>Settings-&nbsp;<wbr></wbr>HC&nbsp;<wbr></wbr>Format菜单中已经限定UF-100向计算机只能传输UF-100的&nbsp;<wbr></wbr>结果，而不允许传输尿十项的结果。&nbsp;<wbr></wbr><br />
            故障处理：但如果按以下方法连接可实现CLINITEK&nbsp;<wbr></wbr>200+的结果能传到计算机上。1，在主计算机分配并设定COM1口和COM2口，UF-100的结果传输到COM1口，尿十项CLINITEK&nbsp;<wbr></wbr>200+的结果传输到COM2口。2，找一条标准的25转9电缆线，从CLINITEK&nbsp;<wbr></wbr>200+的打印口连到主计算机的COM2口即可。<br />
            <h3><span>UF-50全自动尿液有形成分分析仪的保养与维修</span>&nbsp;<wbr></wbr></h3>
            <p>UF-50是日本sysmex公司生产的全自动尿有形成分分析仪，在<a href="http://www.39kf.com/focus/lc/" target="_blank">临床</a>实验中用来分析尿液的有形成分。该仪器可以非常准确地筛选出异常标本，同时提高实验室的自动化水平和检测效率。</p>
            <p>　　UF-50是采用流式细胞术检测方法对尿液有形成分进行分析。通过荧光染色的方法，UF-50对尿液的有形成分自动分类。从吸取尿样到输出结果，系统的所有操作过程，都实现了自动化。为了保证仪器的正常使用和测量结果的准确性，下面主要介绍一般的常规保养，所介绍的保养是根据一般的使用环境所设定的保养周期，以供大家参考。<br />
            &nbsp;<wbr></wbr><br />
            　<strong>　1&nbsp;<wbr></wbr> 每天的保养<br />
            </strong>&nbsp;<wbr></wbr><br />
            　　1.1&nbsp;<wbr></wbr> 执行关机程序&nbsp;<wbr></wbr> 清洁进样针和Flow Cell（执行关机）执行关机程序之后，进样针和Flow Cell就被清洗好了。结束一天的工作之后要执行关机程序，或者在当仪器连续使用时每24h至少执行1次。（1）按下功能菜单中的［shut down］键。（2）将会出现关机执行的窗口。（3）将CELLCLEAN瓶放于进样针下方，然后按［MANUAL START］键，保持CELLCLEAN瓶直到进样针上升；（4）关机程序开始；（5）当关机程序结束之后，将会响起报警声，并出现关机结束屏幕；（6）当结束操作的时候，在此状态下关闭电源。关闭电源按以下步骤进行：1&gt;主机单元；2&gt;激光单元；3&gt;激光变压器单元；4&gt;压缩机单元；5&gt;打印机。<br />
            &nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr><br />
            　　1.2&nbsp;<wbr></wbr> 检查防逆流室&nbsp;<wbr></wbr> 当结束了当天的分析之后，检查防逆&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr> 流室并清除任何积留的液体。（1）验证压缩机单元的压力表是否指向0；（2）将防逆流室逆时针转动，并取下它；（3）清除任何积留的液体，然后将防逆流室重新安上。<a href="http://www.39kf.com/"><img title="Sysmex&nbsp;&lt;wbr&gt;UF-100/UF-50尿沉渣分析仪常见故障维修" alt="这" src="http://www.39kf.com/Txt2Img/dddddddddddddddd43.gif" border="0" real_src="http://www.39kf.com/Txt2Img/dddddddddddddddd43.gif" /></a>时要证实浮球已被放进防逆流室中。<br />
            &nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr><br />
            　<strong>　2&nbsp;<wbr></wbr> 每周的保养<br />
            </strong>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>&nbsp;<wbr></wbr><br />
            　　清理进样过滤器:（1）关掉主机单元的电源；（2）等1min后释放压力；（3）打开主机单元前面板底部的进样过滤器保护盖（推开盖子）；（4）将进样过滤器从其固定器上移开；（5）移走管子的支撑（右边）；（6）将清洁注射器连接到拆下来的进样过滤器上，并将容器放在接近于吸液器顶部的位置。然后反复吸入和排干CELLCLEAN来清洁过滤器；（7）用水代替CELLCLEAN，然后再以与（6）相同的步骤清洁进样过滤器。（8）以拆卸进样过滤器相反的次序重新安装它。</p>
            <p>　　<strong>3&nbsp;<wbr></wbr> 需要时的保养</strong></p>
            <p>　　当废液箱满了的时候，你就有必要<a href="http://www.39kf.com/"><img title="Sysmex&nbsp;&lt;wbr&gt;UF-100/UF-50尿沉渣分析仪常见故障维修" alt="更" src="http://www.39kf.com/Txt2Img/kkk556728.gif" border="0" real_src="http://www.39kf.com/Txt2Img/kkk556728.gif" /></a>换一<a href="http://www.39kf.com/"><img title="Sysmex&nbsp;&lt;wbr&gt;UF-100/UF-50尿沉渣分析仪常见故障维修" alt="个" src="http://www.39kf.com/Txt2Img/ksdfuie4557.gif" border="0" real_src="http://www.39kf.com/Txt2Img/ksdfuie4557.gif" /></a>。更换废物容器，当废液箱满了的时候，用下列步骤替换它：（1）关掉主机单元的电源；（2）等1min后释放压力；（3）准备一个空的废液箱并去掉瓶盖；（4）将管子从满了的废液箱中拉出来；（5）将管子插入一个新的废液箱中并用粘性胶带或其他类似的东西将其固定。<br />
            &nbsp;</p>
            </div>
            </td>
        </tr>
    </tbody>
</table>
</p>]]>
</description>
<guid isPermaLink="false">http://www.bokee.net/blogmodule/weblogcomment_viewEntry/10008673.html</guid>
<subject></subject>
<author>dianziweixiu</author>
<category></category>
<pubDate>Wed, 18 Jan 2012 15:59:41 CST </pubDate>
</item>

<item>
<title>德尔格呼吸麻醉回路/管路/呼吸雾化器/气管延长管销售</title>
<link>http://www.bokee.net/blogmodule/weblogcomment_viewEntry/10008642.html</link>
<description>
<![CDATA[<p>电话13391816794 QQ283536127</p>
<p>
<table cellspacing="0" cellpadding="0" width="31146" border="0" nowrap="true" style="table-layout: fixed">
    <tbody>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" style="border-bottom: medium none">重用型呼吸麻醉回路</td>
            <td nowrap="nowrap" style="border-bottom: medium none">　</td>
            <td nowrap="nowrap" style="border-bottom: medium none">　</td>
            <td nowrap="nowrap">　</td>
            <td nowrap="nowrap">&nbsp;</td>
            <td nowrap="nowrap" align="left" colspan="2" style="border-right: windowtext 0.5pt solid">未注明最小起订量要求的，均无起订量要求</td>
            <td nowrap="nowrap" colspan="249" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" x:num="8413146" style="border-bottom: medium none">8413146</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none; border-bottom: medium none">Savina成人呼吸回路(Savina专用)</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1根</td>
            <td nowrap="nowrap" align="center" x:num="6687.5">&nbsp;</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" x:num="8412344" style="border-right: medium none; border-bottom: medium none">8412344</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none; border-bottom: medium none">Savina小儿呼吸回路(Savina专用)</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1根</td>
            <td nowrap="nowrap" align="center" x:num="7080">&nbsp;</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" style="border-bottom: medium none">8412092</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none; border-bottom: medium none">通用型成人呼吸回路(Aquapor湿化器用)</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1根</td>
            <td nowrap="nowrap" align="center" x:num="6687.5">&nbsp;</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" x:num="8414986" style="border-right: medium none; border-bottom: medium none">8414986</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none; border-bottom: medium none">Evita成人呼吸回路(F&amp;P850湿化器用)</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1根</td>
            <td nowrap="nowrap" align="center" x:num="7555">&nbsp;</td>
            <td valign="top" nowrap="nowrap" align="left" width="162" height="20">
            <div style="text-align: left"><font size="+0">8414986</font></div>
            LeftTop
            <table cellspacing="0" cellpadding="0">
                <tbody>
                    <tr>
                        <td nowrap="nowrap" width="162" height="20">&nbsp;</td>
                    </tr>
                </tbody>
            </table>
            </td>
            <td nowrap="nowrap" colspan="251" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" x:num="8414987" style="border-right: medium none">8414987</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none">Evita小儿呼吸回路(F&amp;P850湿化器用)</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1根</td>
            <td nowrap="nowrap" align="center" x:num="9027.5">&nbsp;</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" x:num="8411041" style="border-right: medium none; border-bottom: medium none">8411041</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none; border-bottom: medium none">Babylog常频硅胶管路</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1根</td>
            <td nowrap="nowrap" align="center" x:num="9287.5">&nbsp;</td>
            <td valign="top" nowrap="nowrap" align="left" width="162" height="20">
            <table cellspacing="0" cellpadding="0">
                <tbody>
                    <tr>
                        <td nowrap="nowrap" width="162" height="20">&nbsp;</td>
                    </tr>
                </tbody>
            </table>
            </td>
            <td nowrap="nowrap" colspan="251" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" x:num="8411153" style="border-right: medium none; border-bottom: medium none">8411153</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none; border-bottom: medium none">Babylog高频HFV管路</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1根</td>
            <td nowrap="nowrap" align="center" x:num="4807.5">&nbsp;</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" style="border-right: medium none; border-bottom: medium none">M30146</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none; border-bottom: medium none">Primus Fabius成人麻醉管路</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1根</td>
            <td nowrap="nowrap" align="center" x:num="8070">&nbsp;</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" style="border-right: medium none; border-bottom: medium none">M33681</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none; border-bottom: medium none">Primus 小儿麻醉管路</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1根</td>
            <td nowrap="nowrap" align="center" x:num="9222.5">&nbsp;</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" style="border-bottom: medium none">一次性呼吸麻醉管路</td>
            <td nowrap="nowrap" style="border-bottom: medium none">　</td>
            <td nowrap="nowrap" style="border-bottom: medium none">　</td>
            <td nowrap="nowrap">　</td>
            <td valign="top" nowrap="nowrap" align="left" width="162" height="20">
            <div style="text-align: left"><font size="+0">8412344</font></div>
            LeftTop
            <table cellspacing="0" cellpadding="0">
                <tbody>
                    <tr>
                        <td nowrap="nowrap" width="162" height="20">&nbsp;</td>
                    </tr>
                </tbody>
            </table>
            </td>
            <td nowrap="nowrap" colspan="251" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" style="border-right: medium none">MP00312</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none">Carina一次性回路含泄漏阀(单价100/根,25根/箱)</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1箱</td>
            <td nowrap="nowrap" align="center" x:num="6250">&nbsp;</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" style="border-right: medium none">MP00313</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none">Carina一次性回路含呼出阀(单价100/根,25根/箱)</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1箱</td>
            <td nowrap="nowrap" align="center" x:num="6250">&nbsp;</td>
            <td valign="top" nowrap="nowrap" align="left" width="162" height="20">
            <table cellspacing="0" cellpadding="0">
                <tbody>
                    <tr>
                        <td nowrap="nowrap" width="162" height="20">&nbsp;</td>
                    </tr>
                </tbody>
            </table>
            </td>
            <td nowrap="nowrap" colspan="251" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" style="border-right: medium none">MP00301</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none">一次性普通麻醉呼吸管路&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>(单价59/根,25根/箱)</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1箱</td>
            <td nowrap="nowrap" align="center" x:num="3687.5">&nbsp;</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" style="border-right: medium none">MP00303</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none">一次性可伸缩型麻醉管路 (单价69/根,25根/箱)</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1箱</td>
            <td nowrap="nowrap" align="center" x:num="4312.5">&nbsp;</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" style="border-right: medium none">MP00300</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none">一次性普通呼吸管路&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>(单价29/根,25根/箱)</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1箱</td>
            <td nowrap="nowrap" align="center" x:num="1812.5">&nbsp;</td>
            <td nowrap="nowrap">&nbsp;</td>
            <td nowrap="nowrap">　</td>
            <td nowrap="nowrap" colspan="250" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" style="border-right: medium none">MP00305</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none">一次性可伸缩型呼吸管路&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>(单价48/根,25根/箱)</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1箱</td>
            <td nowrap="nowrap" align="center" x:num="3000">&nbsp;</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" style="border-right: medium none; border-bottom: medium none">MP00315</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none; border-bottom: medium none">同轴型呼吸管路&nbsp;<wbr></wbr>&nbsp;<wbr></wbr>(单价99/根,20根/箱)</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1箱</td>
            <td nowrap="nowrap" align="center" x:num="4950">&nbsp;</td>
            <td valign="top" nowrap="nowrap" align="left" width="162" height="20">
            <div style="text-align: left"><font size="+0">8411153</font></div>
            LeftTop
            <table cellspacing="0" cellpadding="0">
                <tbody>
                    <tr>
                        <td nowrap="nowrap" width="162" height="20">&nbsp;</td>
                    </tr>
                </tbody>
            </table>
            </td>
            <td nowrap="nowrap" colspan="251" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" colspan="2" style="border-bottom: medium none; mso-ignore: colspan">呼吸雾化器/气管延长管</td>
            <td nowrap="nowrap" style="border-bottom: medium none">　</td>
            <td nowrap="nowrap">　</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" x:num="8412935" style="border-right: medium none">8412935</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none">气动式雾化器(Evita)</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1个</td>
            <td nowrap="nowrap" align="center" x:num="2750">&nbsp;</td>
            <td valign="top" nowrap="nowrap" align="left" width="162" height="20">
            <table cellspacing="0" cellpadding="0">
                <tbody>
                    <tr>
                        <td nowrap="nowrap" width="162" height="20">&nbsp;</td>
                    </tr>
                </tbody>
            </table>
            </td>
            <td nowrap="nowrap" colspan="251" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" x:num="8411030" style="border-right: medium none">8411030</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid">小儿雾化器(Babylog)</td>
            <td nowrap="nowrap" align="center">1个</td>
            <td nowrap="nowrap" align="center" x:num="2995">&nbsp;</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" x:num="8402041" style="border-right: medium none">8402041</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid">气管延长管 重复使用型</td>
            <td nowrap="nowrap" align="center">1根</td>
            <td nowrap="nowrap" align="center" x:num="495">&nbsp;</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" style="border-right: medium none">MP02400</td>
            <td nowrap="nowrap" align="center" style="border-right: medium none">德尔格原产模拟肺</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid; border-bottom: medium none">1个</td>
            <td nowrap="nowrap" align="center" x:num="4000">&nbsp;</td>
            <td valign="top" nowrap="nowrap" align="left" width="162" height="20">
            <div style="text-align: left"><font size="+0">M30146</font></div>
            LeftTop
            <table cellspacing="0" cellpadding="0">
                <tbody>
                    <tr>
                        <td nowrap="nowrap" width="162" height="20">&nbsp;</td>
                    </tr>
                </tbody>
            </table>
            </td>
            <td nowrap="nowrap" colspan="251" style="mso-ignore: colspan">　</td>
        </tr>
        <tr height="20" style="mso-height-source: userset">
            <td nowrap="nowrap" align="center" style="border-right: medium none">MP02405</td>
            <td nowrap="nowrap" align="center" style="border-right: windowtext 0.5pt solid">可调顺应性阻抗与泄漏值的模拟肺</td>
            <td nowrap="nowrap" align="center">1个</td>
            <td nowrap="nowrap" align="center" x:num="26645">&nbsp;</td>
            <td nowrap="nowrap" colspan="252" style="mso-ignore: colspan">　</td>
        </tr>
    </tbody>
</table>
</p>]]>
</description>
<guid isPermaLink="false">http://www.bokee.net/blogmodule/weblogcomment_viewEntry/10008642.html</guid>
<subject></subject>
<author>dianziweixiu</author>
<category></category>
<pubDate>Wed, 18 Jan 2012 15:57:38 CST </pubDate>
</item>

<item>
<title>美国贝克曼库尔特血凝仪系列生化仪系列血球仪系列化学发光仪系列配件维修销售</title>
<link>http://www.bokee.net/blogmodule/weblogcomment_viewEntry/9952988.html</link>
<description>
<![CDATA[<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 维修电话13391816794&nbsp; QQ283536127</p>
<p>贝克曼库尔特ACL-7000/8000/9000/200血凝仪维修&nbsp;<wbr></wbr>ACL-7000/8000/9000电源维修&nbsp;<wbr></wbr>ACL-7000/8000/9000电路板维修<br />
&nbsp;</p>
<p>贝克曼库尔特CX4/cx5/<wbr></wbr><wbr></wbr>cx7/<wbr></wbr>cx9生化分析仪维修&nbsp;CX4/<wbr></wbr>cx5/cx7/cx9生化分析仪电脑板维修&nbsp;<wbr></wbr>电源维修&nbsp;<wbr></wbr>主机电路板维修&nbsp;</p>
<p>贝克曼库尔特三分类血球分析仪维修&nbsp;<wbr></wbr>贝克曼库尔特五分类血球分析仪维修&nbsp;<wbr></wbr>贝克曼库尔特血球分析仪主板维修&nbsp;<wbr></wbr>贝克曼库尔特血球分析仪电源维修<br />
&nbsp;</p>
<p><wbr></wbr><font size="4">美国贝克曼ACESS化学发光分析仪维修 电源维修 电路板维修 </font><br />
&nbsp;</p>
<p><font size="2"><font color="#cc0000">化学发光贝克曼</font>Access2 全自动免疫分析仪维修 电源维修 电路板维修 </font></p>
<p><font size="2"><img height="375" width="500" alt="" src="http://fs01.bokee.net/userfilespace/2012/01/13/dianziweixiu16906089.jpg" /><img height="375" width="500" alt="" src="http://fs01.bokee.net/userfilespace/2012/01/13/dianziweixiu16906100.jpg" /><img height="375" width="500" alt="" src="http://fs01.bokee.net/userfilespace/2012/01/13/dianziweixiu16906110.jpg" /><img alt="" src="http://fs01.bokee.net/userfilespace/2012/01/13/dianziweixiu16906119.jpg" />美国贝克曼库尔特有限公司是一家开发和销售仪器，生化，软件以及能够简化和自动化实验室处理产品的公司。该公司的产品能够支持在与疾病战斗的各个阶段的生物医学分析－从前沿医学研究到患者血液检测。在2004年，公司销售额为 24亿美元，其中70%的销售额来自临床诊断市场，30%来自生物医学研究市场。稀释后每股收入(不包括特种费用/特别信贷)为.82。 </font></p>
<div class="spctrl">&nbsp;</div>
<p>　　贝克曼库尔特提供了一个广泛的分离，检测和分析生命组成部分的仪器业务。在医院临床实验室中，公司可以提供实际意义上的各种常规血液检测以及75%的其它检测。他们的70%以上的产品都保持在市场高端位置上：血液学，常规生化系统，离心，毛细管电泳，蛋白质分析，生物机器人以及快速检测。</p>
<div class="spctrl">&nbsp;</div>
<p>　　公司系统的客户包括遍布全球的制药和生物技术公司，大学，医疗学院，研究机构，医院， 医师办公室，以及诊断实验室。贝克曼库尔特目前在全球范围内的实验室中拥有大约200,000主要的仪器系统，操作系统售后服务，生化试剂盒以及服务合同等代表了大约总收入的64％。</p>
<div class="spctrl">&nbsp;</div>
<p>　　贝克曼重组于1988年， 在从SmithKline Beckman公司抽资脱离以后。在1998年，公司名称更改为美国贝克曼库尔特有限公司，反映出1997年与库尔特公司的并购关系。</p>
<div class="spctrl">&nbsp;</div>
<p>　　业务概述</p>
<div class="spctrl">&nbsp;</div>
<p>　　核心策略</p>
<div class="spctrl">&nbsp;</div>
<p>　　贝克曼库尔特将使用简化和自动化客户处理的系统创建一个值，使其能够改进由经济或收益机制进行衡量的的生产力。</p>
<div class="spctrl">&nbsp;</div>
<p>　　关键的支持策略</p>
<div class="spctrl">&nbsp;</div>
<p>　　I. 优化和调控核心业务</p>
<div class="spctrl">&nbsp;</div>
<p>　　II. 围绕生物医学检测一体化扩展检测和技术</p>
<div class="spctrl">&nbsp;</div>
<p>　　III. 瞄准高度增长的机遇</p>
<div class="spctrl">&nbsp;</div>
<p>　　把握整体</p>
<div class="spctrl">&nbsp;</div>
<p>　　贝克曼库尔特产品计划通过将我们客户的生产和效率整合到其实验室处理来使其得到改进。我们的每个分析&ldquo;系统&rdquo;都包括仪器，软件以及耗材，如试剂，生化，样品小瓶等等。系统的购买过程包括最开始的&ldquo;需求评估&rdquo;，售后客户培训，应用支持以及长期服务。</p>
<div class="spctrl">&nbsp;</div>
<p>　　整合共有技术</p>
<div class="spctrl">&nbsp;</div>
<p>　　贝克曼库尔特在生化，工程以及软件科学方面，为其所有客户提供了一个通用的成套技术支持。这些核心技术允许我们的公司调控其研究和开发投资，同时为生物医学研究和患者护理中的仪器和试剂系统提供一个整合范围。对基本研究市场的参与，使贝克曼库尔特得以更早的涉足新的开发，并在不久的将来从发现阶段转入临床研究过程，最终在常规患者护理中实现应用。</p>
<div class="spctrl">&nbsp;</div>
<p>　　<b>实验室自动化&ndash; 临床诊断</b>（略）</p>
<div class="spctrl">&nbsp;</div>
<p>　　<b>实验室自动化</b> &ndash; 生物医学研究：即时检验、血液学（略）</p>
<div class="spctrl">&nbsp;</div>
<p>　　<b>生物医学业务</b>：离心及仪器系统、自动机械自动化 &amp; 遗传分析、专业检测、并购，协议与合作（略）</p>
<div class="spctrl">&nbsp;</div>
<p>　　公司组织</p>
<div class="spctrl">&nbsp;</div>
<p>　　劳动力：到2003年12月31日为止，贝克曼库尔特在全球范围内的员工人数达到大约9,882人。公司在培训和员工开发，尤其是质量，安全，技术以及其它基于性能的技术方面的开发工作上都进行了大量的资金投入。</p>
<div class="spctrl">&nbsp;</div>
<p>　　员工分类：管理15%；生产27%；研发13%；销售，服务及市场分布45%。</p>]]>
</description>
<guid isPermaLink="false">http://www.bokee.net/blogmodule/weblogcomment_viewEntry/9952988.html</guid>
<subject></subject>
<author>dianziweixiu</author>
<category></category>
<pubDate>Fri, 13 Jan 2012 10:46:55 CST </pubDate>
</item>

<item>
<title>SYSMEX配件 希森美康配件 东亚配件 SYSMEX仪器维修 希森美康仪器维修</title>
<link>http://www.bokee.net/blogmodule/weblogcomment_viewEntry/9946549.html</link>
<description>
<![CDATA[<p>
<table cellspacing="0" cellpadding="0" width="100%" border="0" style="font-weight: normal; word-break: break-all">
    <tbody>
        <tr>
            <td height="25"><span style="word-break: break-all">东亚K系列血细胞分析仪的故障分析&nbsp; </span><strong><span style="word-break: break-all">电话13391816794 QQ283536127<br />
            </span></strong></td>
        </tr>
        <tr>
            <td>
            <p>SYSMEX配件 希森美康配件 东亚配件 SYSMEX仪器维修 希森美康仪器维修</p>
            <p>电源维修 电路板维修 电话13391816794 QQ283536127<br />
            &nbsp;</p>
            </td>
        </tr>
        <tr>
            <td valign="top" align="left" colspan="2" height="300" style="word-break: break-all">
            <table cellspacing="0" cellpadding="10" align="left" border="0">
                <tbody>
                    <tr>
                        <td>&nbsp;</td>
                    </tr>
                </tbody>
            </table>
            <div align="left">日本东亚医用电子株式会社(现改为希森美康)生产的SYSMEX系列血细胞分析仪是全球三大著名品牌之一，其中的三分类K系列(包括K-1000型、K-4500型和KX-21型) 血细胞分析仪在我国的一些大中型医院使用比较普遍。虽然它从设计上把液路系统和气路系统分开减少了故障的发生率，并且利用高压电灼烧产生的空气锤进行排阻降低了阻孔的产生，但它仍然会出现一些问题。现把我们平时工作中遇到的故障总结如下，希望能起到抛砖引玉的作用。<br />
            <br />
            故障现象1：K-4500型显示&ldquo;400mmHg负压错误&rdquo;，不能继续进行测试。<br />
            <br />
            K-4500型血细胞分析仪在工作是需要监测4个压力值：400mmHg原始负压、250mmHg标准负压、0.5kg/cm2正压、2.2 kg/cm2正压(注意：KX-21型只监视0.5kg/cm2正压和250mmHg负压)。这几个压力机器都限定了一个正常范围，如果有一个压力超过了正常范围，机器就会报警并停止测试样本。该故障现象是400mmHg原始负压偏高并且不稳定，但是250mmHg标准负压稳定在正常范围内，检查管路图，发现从压缩机中出来的负压经过空气过滤器&rarr;防逆流器&rarr;400mmHg压力检测管道&rarr;限流器&rarr;250mmHg压力调整器&rarr;250mmHg压力检测管道。250mmHg压力正常而400mmHg压力偏高，从管道上看，可能是由于限流器、空气过滤器、防逆流器或中间管道发生阻塞造成内部负压偏高，仔细检查管道、空气过滤器、防逆流器无阻塞，拆下机器左侧面的限流器进行冲洗，对它的限流孔进行清通，装上重新进行监测故障依旧。现在只有检查400mmHg压力检测管道和压力传感器，打开机器上盖，取出NO.2116PCB印制板，板上有四个压力传感器。找到监测400mmHg压力的传感器，发现在连接传感器的管道中有液体存在，排除掉液体，进行压力传感器调校，正常工作时：偏移量调校，不加压时，调整VR11，使TP24&rarr;TP1电压为0&plusmn;20 mV；增益调校，施加250mmHg压力，调整VR10，使TP24&rarr;TP1电压为975&plusmn;20 mV。但是压力传感器调校点完全不能调整到位。再用一根细铜丝分别伸入四个传感器的测压口进行对比，发现铜丝进入监测400mmHg压力传感器的深度与其它三个不同，要深一些，至此，完全可断定由于含有盐分的液体进入管道，造成对传感器里的应变片腐蚀穿透使压力监测不正确，更换NO.2116PCB印制板后重新开机故障排除。<br />
            <br />
            故障现象2：KX-21型不论是检测空白还是样本，WBC重复性都不好。<br />
            <br />
            首先检查稀释液是否原厂配置；排除掉试剂的因素，拆下旋转阀用清洗液反复进行清洗，然后再用蒸馏水进行冲洗，拆下WBC检测容器，清洗内电极并调整内电极的位置，安装好旋转阀和WBC检测容器后重新进行检测，故障依旧。排除掉管道引起故障的可能性后就开始检查电气部分，仔细检查，发现WBC的外电极的连接插头处有水迹，拔掉保护套，用电吹风加热插头部分，重新连接好后进行空白和样本的检测，重复性很好，故障排除。估计是由于WBC容器的塞子松动造成溶液泄漏，顺着外电极连接线流进插头使测试信号受到干扰使重复性变差。<br />
            <br />
            故障现象3：KX-21型不论如何冲洗，始终出现空白检测错误。<br />
            <br />
            由于该机曾经出现过程序执行出错的故障，而且在检修过程中，供电的稳压器电压不稳且保险丝被熔短，因此首先观察机器的执行过程。打开检测部盖子，发现盖右下部有水，擦干水迹，观察检测器部分，发现检测空白时，WBC一侧打入的稀释液量比较准确，而RBC一侧连续打入两次稀释液，使检测容器中的液面超过了防溢出装置，从侧面的防溢出管道流出来，从现象上看，以为程序出错，调出维修菜单对机器进行初始化，关机然后重新开机检测空白，故障依旧。重新观察机器执行过程，发现左侧的RBC混匀器中始终没有进液体，而且正常时，取了RBC稀释好的样本后，混匀器应该还有一定的余量，怀疑阻塞。观察旋转阀动作及周围管道情况，发现旋转阀始终没有动作，排除掉汽缸阻塞的原因，结果是旋转阀卡死。检查结果是：在检测样本时，电源出现异常，且由于阀内有大量结晶体，使阀停止在中间位置卡死，而吸取的样本在管道内凝结发生阻塞，用清洗液清洗旋转阀内表面和去除凝结的样本，安装好旋转阀重新开机检测空白，空白值都在机器规定的范围内。<br />
            <br />
            故障现象4：K-4500型或KX-21型出现提示更换稀释液。<br />
            <br />
            首先检查稀释液是否用完，没有则更换稀释液；检查稀释液室中的浮式开关是否完好并可以自由活动，避免有结晶存在；检查负压是否正常，若负压过低，检查负压管道是否有漏气，检查压缩机的密封圈和叶阀，如果没有问题则按下述步骤进行原始负压的确认：<br />
            <br />
            a. 打开机壳；<br />
            <br />
            b. 在&rdquo;维护&rdquo;菜单中选&rdquo;状态显示&rdquo;；<br />
            <br />
            c. 从负压调整风箱底部断开管子，仪器出现蜂鸣声，负压显示为0，按C键取消蜂鸣；<br />
            <br />
            d. 用手按住管口，观察负压，原始值应为700mmHg，从0上升到700mmHg约要10～15秒；<br />
            <br />
            e. 调整负压到正常值(250mmHg);<br />
            <br />
            如果原始负压过低就更换压缩机，若负压为0，检查逆流防止室(在左侧面)里面液体和浮球的状态；旋转阀的汽缸漏气使正压不够，导致吸引稀释液时阀不能完全打开，一种解决方法是更换汽缸两头和中间轴上的密封圈，另一种暂时解决的方法是在杆的上部和下部涂上粘度高的润滑剂(如医院常见的凡士林)。<br />
            <br />
            故障现象5：KX-21型WBC分类分不出来。<br />
            <br />
            检查测试样本的报告单，发现上午测试的样本普遍不能对WBC进行分类，而下午的情况相对好转，加上当时正是冬季，而检查发现室内无任何加热或恒温装置，怀疑是由于稀释液和溶血素的温度太低，使细胞溶血不能正常进行导致分类不正常，把溶血素在25℃的水箱中进行水浴半小时，取出重新进行样本测试分类正常。该故障提醒使用者：一定要给仪器一个合适的使用环境(包括稳定的电源、接地、温度、空气洁净度等)，不然会带来一些不必要的故障。<br />
            <br />
            故障现象6：KX-21型吸引针下部有少量液体下滴。<br />
            <br />
            首先了解一下吸引针和清洗杯的工作过程：清洗杯下降时，同时注入清洗液，吸引针周围的血随清洗液一起被吸入废液瓶，为了清洗全血吸引管路，当清洗杯到达吸引针的底部时，清洗液(包括血液)从针尖冲出并被吸引到废液瓶中，当清洗杯往上移动时，清洗液既不会吐出，也不会吸引到吸引针内。了解了工作过程，先观察这些液体是从针孔内出来还是针外部。如液体是从针孔内出来，则可能是吸引针、旋转阀或管道系统发生阻塞从而造成内部吸引负压不够，使针内液体倒流。拆下旋转阀用清洗液清洗，清洗吸引针或检查管道系统；如果液体是在吸引针外部，则可能是吸引清洗杯中清洗液的250mmHg压力过低，只需调节机器左侧面的250mmHg压力旋钮使吸样时无液体即可。<br />
            <br />
            故障现象7：KX-21或K-4500型分析之中压缩机突然停机。<br />
            <br />
            为了避免压缩机长时间动作引起温度升高或不必要的动作加速其老化，KX-21和K-4500都有压缩机温度监测和15分钟不进样(可人为设定)保护停机功能。压缩机突然停机，首先检查压缩机是否有损坏；压缩机散热不良使温度升高引起保护性停机；检查一下压缩机的散热风扇动作是否正常；压缩机的温度保护器接触金属部分或者发生故障引起停机。</div>
            </td>
        </tr>
    </tbody>
</table>
</p>]]>
</description>
<guid isPermaLink="false">http://www.bokee.net/blogmodule/weblogcomment_viewEntry/9946549.html</guid>
<subject></subject>
<author>dianziweixiu</author>
<category></category>
<pubDate>Thu, 12 Jan 2012 16:01:03 CST </pubDate>
</item>

<item>
<title>西门子Sequoia512，Sequoia S512,Sequoia C512彩超维修配件销售</title>
<link>http://www.bokee.net/blogmodule/weblogcomment_viewEntry/9831833.html</link>
<description>
<![CDATA[<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px"><font color="#800000"><b><img height="751" width="500" alt="" src="http://fs01.bokee.net/userfilespace/2012/01/04/dianziweixiu16653197.jpg" /></b></font>
<p align="left" style="margin-top: 0px; margin-bottom: 0px"><font color="#800000"><b>提供</b></font>美国产西门子（SIEMENS）红杉树<span lang="zh-cn">（SEQUOIA)512</span>高档彩超</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">可根据用户需求提供各种配置，各种版本的红杉树系列彩超（版本：V7，9，10，12）并提供全套探头（3V2C,<span lang="zh-cn">15L8W,4C1,6C2，EC10C5,EV8C4,4V1C等）</span>及电路板（BDM2，RDP，IOV，CSD2，CN1，2，BF3）</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px"><b><font color="#ff0000" size="4">我公司可以：</font></b></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px"><font color="#ff0000" size="4"><b>1</b></font><b><font color="#ff0000" size="4">.维修任何版本的西门子 Sequoia512，<span lang="zh-cn">Sequoia S512,Sequoia C512,SequoiaC256等，</span></font><span lang="zh-cn"><font color="#ff0000" size="4">全套现货电路板，电源等，经过厂家培训的高水平工程师，可以以最快的速度，恢复你的机器。</font></span></b></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px"><span lang="zh-cn"><font color="#ff0000" size="4"><b>2</b></font></span><b><font color="#ff0000" size="4"><span lang="zh-cn">.恢复你密码丢失的机器，开通你感兴趣的选件。</span></font></b></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px"><span lang="zh-cn"><font color="#ff0000" size="4"><b>3</b></font></span><b><font color="#ff0000" size="4"><span lang="zh-cn">.软件硬件升级，CRT 升级液晶显示器，可以将你的老SEQUOIA 256，升级到最新版本的SEQUOIA512 ，12.221版本。</span></font></b></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px"><span lang="zh-cn"><font color="#ff0000" size="4"><b>4.保修服务。可签订机器及探头保修服务，免除你的后顾之忧。</b></font></span></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px"><b><font color="#ff0000" size="4"><span lang="zh-cn">&nbsp;&nbsp; 超低价格，一流服务，一流速度，包您满意。</span></font></b></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;</p>
</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">1.<span lang="zh-cn">全球公认的高端彩超，图像一流，机器稳定性一流。</span></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px"><span lang="zh-cn">&nbsp;&nbsp; 具有其它彩超无法比拟的辉煌历史和销售量。</span></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">2.高质量超声图像的终结者，至今无其它机器能够超</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;&nbsp; 越<span lang="zh-cn">。得到全世界使用医生的交口称赞。</span></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">3.Native TEQ&trade;，西门子独有的图像增强技术，极大地</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;&nbsp; 改善了图像质量。</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">4.512<span lang="zh-cn">真实超声发射采集通道。保证了足够细腻的超声</span></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px"><span lang="zh-cn">&nbsp;&nbsp; 图像。</span></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px"><span lang="zh-cn">5.高分辨率彩色多普勒血流图像。通过对彩色血流信号</span></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px"><span lang="zh-cn">&nbsp;&nbsp; 的特殊编码方式来定位空间分辨率，极大地改善了穿</span></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px"><span lang="zh-cn">&nbsp;&nbsp; 透力，提高了对低速血流的灵敏度，以及强大的微细</span></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px"><span lang="zh-cn">&nbsp;&nbsp; 血管的探测能力。</span></p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">6.Cadence&trade; contrast pulse sequencing technology。</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;&nbsp; 超声界最灵敏的对比成像技术，利用基波超声和谐波</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;&nbsp; 超声，大大增强你的诊断手段和信心。</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;&nbsp; 总而言之SEQUOIA（红杉树），超声诊断的王者，</p>
<p align="left" style="margin-top: 0px; margin-bottom: 0px">&nbsp;&nbsp; 你的不二选择。</p>
<p>西门子彩超销售&nbsp;西门子彩超配件销售&nbsp;西门子彩超维修&nbsp;西门子彩超电源维修&nbsp;西门子彩超显示器维修&nbsp;西门子彩超显示屏维修&nbsp;西门子彩超电路板维修<em>&nbsp;电话13391816794&nbsp;QQ283536127</em></p>
<p>西门子：&nbsp;中狮王、欧米娜、G20,&nbsp;G50,&nbsp;G60S,&nbsp;Antares,&nbsp;Sequoia&nbsp;C256,&nbsp;Sequoia&nbsp;512&nbsp;(液晶和CRT)，</p>
<p>X150 X300 S2000 SC2000 等等西门子配件</p>]]>
</description>
<guid isPermaLink="false">http://www.bokee.net/blogmodule/weblogcomment_viewEntry/9831833.html</guid>
<subject></subject>
<author>dianziweixiu</author>
<category></category>
<pubDate>Wed, 04 Jan 2012 10:47:07 CST </pubDate>
</item>

</channel>
</rss>
